Honeywell T775
With The T775, You’ll Know You Have Exactly What You Need, Because All The Features Are Self-Contained
Some controllers require you to piece together separate modules to get the control features you want, and those added relays can, well, add up. So can the added LCD display, an added transformer module and more. The Honeywell T775 Electronic Standalone Controller puts an end to add-on costs. All the features you need for a variety of applications are built right into the T775, including the LCD display. You won’t have to worry about having the right modules in stock or needing to piece them together. The T775 has it all.
It’s All Inside
- Easy-To-Use Graphical Interface — Operating the new T775 is as easy as operating your cell phone. The easy-to-use, intuitive programming will save you time on every job.
- Internal Time Clock Scheduler — The Setback and Disable Output options, controlled by the built-in scheduler or digital input, will help save energy during unoccupied times and give you more control of the equipment without needing to purchase an additional time clock.
- Up To Two Independent Modulating Outputs — Each output can be individually configured for 0-10 Vdc, 2-10 Vdc, 4-20 mA or Series 90, so a single device can handle many field requirements to save you time selecting the right control for the job.
- NEMA 4X Enclosure Option — Certain models are offered with NEMA 4X enclosures to protect them from water and corrosion. They can be installed in animal confinement areas, green houses, washdown areas, swimming pools and other similar locations, giving you the control you need for harsh locations.
- Modulating High Or Low Limit Control — If you need to protect your coil from freezing or your equipment from overheating, models offering this feature give you the ability to adjust your control temperature at sensor A to protect equipment at sensor B. You get consistent control while still protecting your equipment.
- Optional Configurable Integral And Derivative Times — Standard on every device, this feature delivers pinpoint control. PI or PID control on modulating outputs is set up by default to behave just like the previous T775 Series 1000, but now you can adjust reaction times and behavior, giving you more control.
- Reset Models With Simplified Setup — Reset programming has never been easier. Simply enter the high and low control temperatures and the corresponding high and low outdoor temperatures, and you’re done. As your outside temperature gets colder, the setpoint temperature automatically adjusts to save energy.
- Configurable Minimum Off Time — If needed, setting a minimum off time can protect equipment and reduce the need for a separate time delay device.
- Sensor Calibration — Calibrate input sensors up to +/-10° F. This can be used to compensate for resistance drops in wire leads, to offset the input temperature for sensor location and more.
- Fewer Models — Fourteen T775 models replace 38 Series 1000 models, so you’ll reduce inventory and eliminate the headache of trying to choose the right model.
Special Models
Several T775 models are designed to ensure your control needs can still be met with a single unit for special applications.
- Universal Model To Control Pressure, Humidity Or Temperature — The T775U Universal model has an easy setup for configuring control of pressure or humidity with a 0-5Vdc, 0-10 Vdc or 4-20 mA input. Control humidity with % RH displayed, CO2 with ppm displayed, or control pressure with in. w.c., psi, Pa, or kPa displayed. Outputs include two modulating and two relay outputs that can each have their own setpoint. The T775U even offers the ability to reset the output based on outdoor temperature — handy when you need to reduce window condensation when setting humidity levels. With the T775U, you’ll enjoy complete versatility in a single control that gives you the freedom to do what the job requires.
- Special Sequencing Model For Staging Up To 12 Relays With Up To Two Setpoints — The sequencer model has four stages, plus you can add up to two optional 4-stage expansion relay modules for 8- or 12-stage operation. The flexible setup allows you to configure these stages for heating, cooling or both. Because sequencer models operate up to 12 stages, you can control multiple low-mass boilers, chillers, electric heat and other equipment from a single controller.
- Special Boiler Model — The T775 boiler model offers features including dedicated pump output, staging for up to 12 relays, digital output alarm, pump exercise, pump pre-purge and post-purge, warm weather shut-down, built-in scheduler, displayed run time, equal run time, first-on, first-off and more. With a single control, you can handle multi-boiler applications. The T775 boiler model can be used on chillers as well.
Models for Standard Applications
Models for Special Applications
Further Information
- T775 Electronic Standalone Controller
- T775S Series 2000 Expansion Module
- T775U Series 2000 Electronic Stand-Alone Controller
- T775L Series 2000 Electronic Stand-Alone Staging Controller
- T775 Application Guide And Cross Reference
- T775 Sales Presentation (ppt)